Wiring: Nurse Call Device

This post outlines the wiring of the Nurse Call device for offline control with Amazon Alexa. To see how this device is connected in the hospital rooms, refer to this post


This outlines the wiring for the offline Nurse Call device using Amazon Alexa. The following design uses the parts listed in a previous post, along with a custom 3-D printed holder for inside of the project box enclosure.


The two 1/4" mono jacks are wired in parallel. One is to be used as an input for a manual call light switch, and the other is to be used as an output for the call light system. One of the poles of the 1/4" mono jack is connected to the COM pin on the relay (Black Wire), and the other is connected to the NO pin (Red Wire). 


The DI06 Pin on the Texas Instruments board is wired to the IN (input) pin on the relay (Green Wire) to trigger momentary closure. The 3.3V pin and GND pin on the Texas Instruments board are wired to the VCC pin (Red Wire) and GND pin (Black Wire) on the relay, respectively.


Wire a 5V 1A input power source to the 5V and GND pins on the Texas Instruments board to provide power to the device. 